KatT2-20190716

Märkische Stanz-Partner AUTONOME GASDRUCKFEDERN / STAND ALONE GAS SPRINGS [NC .030.1 ] [NC] NC.030.00.00420 420 daN 6 - 50 mm Ø25 NC.030.00.00420...1 420 daN 6 - 50 mm Ø25 NC.030.00.03000...1 2945 daN 10 - 50 mm Ø63 NC.030.00.03000...2 2945 daN 10 - 65 mm Ø63 NC.030.00.00770...1 735 daN 6 - 50 mm Ø32 NC.030.00.00770...2 735 daN 6 - 50 mm Ø32 NC.030.00.07500 7540 daN 10 - 50 mm Ø95 NC.030.00.07500...1 7540 daN 10 - 50 mm Ø95 NC.030.00.01800 1885 daN 6 - 50 mm Ø50 NC.030.00.01800...1 1885 daN 6 - 50 mm Ø50 NC.030.00.18300...1 18410 daN 10 - 50 mm Ø150 NC.030.00.18300 18410 daN 10 - 50 mm Ø150 NC.030.00.04700 4675 daN 10 - 50 mm Ø75 NC.030.00.04700...1 4675 daN 10 - 65 mm Ø75 NC.030.00.01000...1 1060 daN 6 - 50 mm Ø38 NC.030.00.01000 1060 daN 6 - 50 mm Ø38 NC.030.00.11800...1 11780 daN 10 - 50 mm Ø120 NC.030.00.11800 11780 daN 10 - 50 mm Ø120 GDF, kompakt GS, compact Technische Information Serie NC.030.00 Beim Einsatz von Gasdruckfedern ist darauf zu achten, dass diese vor Schmutz, Ziehölen und sonstigen Fluiden geschützt werden. Zwar verfügen die meisten Gasdruckfedern über einen Schmutzabstreifer, der das Eindringen von Fremdkörpern verhindern soll, allerdings besteht der beste Schutz darin, erst gar keine Verunreinigung an die Zylinder kommen zu lassen. Die Gasdruckfedern der NC.030 -Serie haben einen besonderen Aufbau (Kol- ben mit Kolbenkopf). Bei diesem Zylinder-Typ entsteht an der Zylinder-Obersei- te ein Saugeffekt, der Flüssigkeiten oder Schmutz in den Zylinder-innenraum ziehen kann. Da sich der Raum für den Stickstoff dadurch verringert, entsteht ein kontinuierlich ansteigender Druck, der letztendlich zum frühzeitigen Ausfall des Zylinders führen kann. Aus diesem Grund müssen die Gasdruckfedern NC.030 konsequent gegen Verunreinigung geschützt werden. Technical information NC.030.00 series Using gas springs it is mandatory to protect them from dirt, oil and similar fluids. For that reason, most springs have a plastic dirt-scraper, to prevent the pene- tration of these external particles. However, the best protection is not to let any dirt get to the springs at all in the first place. Due to the specific design of the NC.030.00 -gas springs there is a „sucking“ effect at the top of the cylinder body. This effect can lead to foreign particles being pulled inside. Since the room designated for the nitrogne thereby con- tinously decreases, the cylinder life - time may be negatively affected. It is for this reason, that the gas springs of this series must be well protected against dirt and fluids. Größenübersicht Serie NC.030.00 Gas spring index NC.030.00 series Gasdruckfeder-Einbau „über Kopf“ mit Draina- ge im Boden / Upside-Down - Appli- cation, drain-hole at the bottom „Wanne“ mit Drainage oben, zusätzlich Boden-Drainage / Cavity with upper drain-hole, additional drain hole at the bottom Gasdruckfeder mit Schutzkappe / Gas spring with protective cover Drainage Schutzkappe / Protective cover Drainage Drainage Wanne / Tub a usl aufend / p hasing ou t a usla ufend / p hasing o ut a usla ufend / p hasing o ut au slaufend / phasing out aus laufend / phasing out auslaufend / phasing out auslaufend / phasing out auslaufend / phasing out a us laufend / phasing out NEU! NEW! NEU! NEW ! NEU! NEW! NEU! NEW! NEU! NEW! NEU! NEW! NEU! NEW! NEU! NEW! NEU! NEW!

RkJQdWJsaXNoZXIy NTYyMTg5